Introduction

The E220R is a 4U rack mount server.

Tested Configurations

Aurora Version

Configuration

Remarks

Reporter

2.99

CPU: 2 x 450MHz UltraSPARC II, RAM: 2GiB, Other: Texas Instruments TVP4020 [Permedia 2] Video Card, pci quad ethernet card

Works

DennisGilmore

Detailed Specifications

Processor

Number

Up to two

Architecture

360- or 450-MHz UltraSPARC[tm]-II

Memory management

MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported contexts

Cache memory

16-KB data and 16-KB instruction on chip per processor

4-MB external per processor

UPA Speed

112.5 MHz

Main Memory

Capacities

16 DIMM module slots

Install SIMMs in sets of four. 64-, and 128-MB DIMM expansion

128 MB to 2 GB total memory capacity (with 128-MB DIMMs, in pairs)

Memory type

60-ns memory modules

Datapath

576 bits wide

Standard Interfaces

Ethernet

One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45) or one MII for external transceiver connection

Keyboard and mouse

One standard keyboard/mouse port (mini DIN-8)

Parallel

One Centronics compatible parallel port (DB25); ECP mode capable

PCI

Four full-size slots compliant with PCI specification version 2.1:

* One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width, 3.3 volt

* Three slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt

SCSI

One 40MB/sec, 68-pin ,Ultra SCSI (SCSI-3), 2 channels (synchronous)

Serial

Two RS-232C/RS423 serial ports (DB25)

Internal Mass Storage

Disks

Up to two 3.5-x 1-in or x 1.6-in. hot-pluggable disks; 9.1-GB, 18.2-GB, or 36.4-GB

CD-ROM/DVD-ROM

32x 644-MB SCSI CD-ROM

10X DVD-ROM

Tape

Optional 12-to 24-GB DDS-3 4mm; 20-to 40-GB 8-mm

Environment

AC input

100 - 240 VAC, 47 - 63 Hz, 6.3 A(max)

Input power

610 W

Heat output

2080 BTU/hr

Temperature1

Operating: 5° C to 35deg; C (41deg; F to 95deg; F)

Nonoperating: -20deg; C to 60deg; C (-4deg; F to 140deg; F)

Humidity

Operating: 20% to 80% relative humidity, noncondensing

Nonoperating: 5% to 93% relative humidity, noncondensing

Altitude

Operating: 3000 m (10,000 ft.)

Nonoperating: 12,000 m (40,000 ft.)

Vibration

Operating: 0.2G peak, 5 - 500 Hz (swept sine)

0.0002 G2/Hz, 5 - 500 Hz (random)

vertical axis only (castered configuration), vertical and horizontal axes (foot glide configuration)

Nonoperating: 1G peak, 5 - 500 Hz (swept sine)

0.002 G2/Hz, 5 - 500 Hz (random)

3 perpendicular axes

Shock

Operating: 4G peak, 11 milliseconds half-sine pulse

Nonoperating: 15G peak, 11 milliseconds half-sine pulse

Number of Cords

1 per power supply; 2 (max)

Regulations

Meets or exceeds the following requirements:

Safety

UL 1950, UL Canada C22.2 No. 950, TUV EN 60950, UL CB Scheme to IEC 950 with full deviations

RFI/EMI

FCC Class A, DOC Class B, VCCI Class A, EN 55022 Class B

Immunity

EN 50082-1

X-ray

DHHS 21 Subchapter J; PTB German X-ray Decree

Dimensions and Weights

Height

17.8 cm (7.0 in.)

43.8 cm (17.25 in.) shipping

Width

43.8 cm (17.25 in.)

60.02 cm (23.63 in.) shipping

Depth

69.2 cm (27.25 in.)

93.98 cm (37.0 in.) shipping

Weight

29.5 kg (65 lb.)

38.6 kg (85 lb.) shipping

Power cord

1.99 m (6.56 ft.)

Clearance and Service Access

Front1

91.4 cm (36 in.)

Rear1

91.4 cm (36 in.)

Right1

91.4 cm (36 in.)

Left1

91.4 cm (36 in.)

Top1

91.4 cm (36 in.)

Rack Mounting

Fits into a standard commercial 19-inch wide, 36-inch deep rack

E220R (last edited 2008-12-26 05:54:29 by localhost)